站内搜索
|
详细信息 Product Name: Medical X-ray Cr System X-ray CCD Any View X-ray Collimator Model NO.: MCX-R160A Certification: ISO13485 Type: X Ray Equipment Classification: Imaging Diagnostic Equipment Medical X-ray Cr System: Good Quality X-ray CCD Any View: Fast Delivery X-ray Collimator: Best Service Static X-ray Machine: 40kHz Rotary Anode Speed: 2800rpm Tube Current: 200mA Tube Voltage: 40kv-125kv Mas: 0.4-360mas Power Supply: 380V 50Hz, Capacity: ?40kVA Medical X-Raymachine: Controlled LCD Touchab Trademark: MeCan Transport Package: Wooden Package for Export Specification: CE Origin: Guangzhou HS Code: 90189070 Product Description Medical X-Ray Cr System X-Ray Ccd Any View X-Ray Collimator25kW High frequency Medical X-ray Radiography SystemModel:MCX-R160ASpecifications of X-Ray machine:Output power3kWX-ray tubeFixed anodeMax height:≥1750mm, Min height:≤500mmRotate around horizontal axis 180°Rotate around vertical axis ±90°Rectifier methodFull-wave rectifierTube voltage40~90kV 9stepsTube current50~90kV 15mA50~90kV 30mA40~80kV 50mAPhotography time50~90kV 15mA 0.1~6.3s50~90kV 30mA 0.1~6.3s40~80kV 50mA 0.1~1.5sPower supply220V±10% 50Hz Inner resistance≤1.0ΩOperation methodsWire control/wireless control (10m) Features of Static X-Ray machine:1. Using ergonomic design, the structure is of compact appearance, convenient operation.2. It adopts high pressure-resistant electrical tube with enough kV and mA, so the definition and contrast of the machine are good.3. With combined X-ray generator, the tube and rocker can move up and down freely. So the patient can take photography in a wider range of direction.4. Because of symmetrical adjustable beam limiting device with light source, the x-ray beam can be adjusted according to demands.5. X-ray generator is matched with protective stereotype inside, and 10 meters wireless remote control exposure is adopted, so it causes less hurt to the operators and environment.6. The current has three gears (15mA, 30mA, 50mA), different current can be selected according to different photography requirements, thus using range of machine is wider.7. Anti-electric shock, anti scattering and full-wave rectifier8. The electric performance is stable and reliable. Multi-protections are adopted to prevent over-voltage, over-current and output overload etc., so it's safer.9. Telescopic vertical rotating angle is larger than 60°.Usage of medical x-raymachine:The machine is mobile X-ray radiography medical diagnostic equipment. It can be used in wards, operation rooms and emergency rooms etc., and it can satisfy the radiography requirements of human body such as head, chest and limbs.Medical X-Ray Cr System X-Ray Ccd Any View X-Ray Collimator
|