Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Guangzhou MeCan Medical Limited  

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Miss Paris Mao
  • 电话:86-20-84835259
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > 12.1 Inch Maternal and Baby Monitor (MCM-9000)
12.1 Inch Maternal and Baby Monitor (MCM-9000)
单价 $9.00 / Piece对比
询价 暂无
浏览 78
发货 Chinaguangdongguangzhou
库存 3000Piece
过期 长期有效
更新 2020-08-20 05:30
 
详细信息
Product Name: 12.1 Inch Maternal and Baby Monitor (MCM-9000) Model NO.: MCM-9000 Certification: CE, SGS, FDA, EEC, MSDS, ISO13485 Type: Patient/Fetal/Maternal Monitor Classification: Imaging Diagnostic Equipment Lead Mode: 5 Leads (R, L, F, N, C or Ra, La, Ll, Rl,V) Lead Selection: I, II, III, AVR, Avl, Avf, V Waveform: 2 CH Sensitivity: > 200 (Uvp-P) Trademark: MeCan Transport Package: Standard Packing for Export Specification: CE FDA Origin: Guangzhou China Product Description 12.1 inch Maternal and Baby MonitorMCM-900012.1" color TFT screenMultichannel displayBig font interfaceST and arrhythmia analysisDrug dose calculation and titration tableOxyCRG dynamic view displayRespiration monitoring with apnea alarmsAlarm review, arrhythmia reviewPatient info. InputAntidefibrillation designNIBP over pressure protectionPlugin rechargeable battery, AC/DC available.Supporting wire or wireless network.Technical SpecificationsECGLead Mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)Lead selection I, II, III, avR, avL, avF, VWavef orm 2 chLead mode 3 Leads ( R, L, F or RA, LA, LL)Lead selection I, II, III,Wave form 1 chGain 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, autoHR and Alarm Range Adult 15 ~ 300 bpm Neo/Ped 15 ~ 350 bpmAccuracy ±1% or±1bpm, which is greaterResolution 1 bpmSensitivity > 200 (uVp-p)Differential Input Impedance > 5 MΩCMRR Monitor > 105 dB Operation > 105 dB Diagnosis > 85 dBElectrode offset potential ±300mVLeakage Current < 10 uAbaseline Recovery < 3 S After Defi.ECG Signal Range ±8 m V ( Vp-p )Bandwidth Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 HzCalibration Signal 1 (mVp-p), Accuracy:5%ST Segment Monitoring Range Measure and Alarm -2.0 ~ +2.0 mVARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP, PNC,Alarm Available,Review AvailableRespirationMethod Impedance between R-F(RA-LL)Differential Input Impedance > 2.5 MΩMeasuring Impedance Range 0.3~3 Ωbase line Impedance Range 200~4 KΩBandwidth 0.1~2.5HzResp. Rate Measuring and Alarm Range Adult 0 ~ 120 Brpm Neo/Ped 0 ~ 150 Brpm Resolution 1 Brpm Accuracy ±2 BrpmApnea Alarm 10 ~ 40 SNIBPMethod OscillometricMode Manual, Auto, STATMeasuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)Measuring Period in STAT Mode 5 MinPulse Rate Range 40 ~ 240 bpmAlarm Type SYS, DIA, MEANMeasuring and alarm range Adult Mode SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Pediatric Mode SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN 20 ~ 165 mmHg Neonatal Mode SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHgResolution 1mmHgAccuracy Maximum Mean error ±5mmHg Maximum Standard deviation ±8mmHgOverpressure Protection Adult Mode 297±3 mmHg Pediatric Mode 240±3 mmHg Neonatal Mode 147±3 mmHgSpO2Measuring Range 0 ~ 100 %Alarm Range 0 ~ 100 %Resolution 1 %Accuracy 70% ~ 100% 2 % 0% ~ 69% unspecifiedActualization intervalabout 1 Sec.Alarm Delay 10 Sec.Pulse Rate Measuring and Alarm Range 20~300 bpm Resolution 1bpm Accuracy ±3bpmTEMPChannel 2Measuring and Alarm Range 0 ~ 50 ºCResolution 0.1 ºCAccuracy ±0.2 ºCActualization intervalabout 1 Sec.Average Time Constant < 10 Sec.IBPLabel ART, PA, CVP, RAP, LAP, ICP, P1, P2Measuring and alarm range ART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP-10 ~ 40 mmHg P1 / P2-10 ~ 300 mmHgPress Sensor Sensitivity 5 uV/V/mmHg Impedance 300-3000ΩResolution 1 mmHgAccuracy ±2% or 1mmHg which is greaterActualization interval about 1 secretaryStandard: ECG, Respiration, NIBP, SpO2, Pulse Rate, TemperatureOptional: Nellcor SpO2, EtCO 2, IBP, Thermal Recorder